IEC 60601-1 Power Supply 120W
- 3” x 2” foot print
- Height 1” above PCB
- 120 Watts with Forced Air Cooling
- Approval to EN60601 3 rd Edition, Dual fusing
- Efficiency upto 93%
- -40 to 70°C operating temperature, Thermal Shut-down protection
- Suitable for BF applications
- Means of Protection : 2xMOPP
- >3.00m Hours, Telcordia -SR332-issue 3
- Standby Power < 0.3W
- Class II option available
Detailed description
Electrical Specifications | |
---|---|
Input Voltage | 85-264 VAC/390 VDC 5 , Universal (see derating under output power) |
Input Frequency | 47 - 63 Hz |
Input Current | 115 VAC – 25 A, 230 VAC – 45 A, 264 VAC – 75 A |
Standby Power | less than 0.3W typical |
Inrush Current | 115 VAC – 25 A, 230 VAC – 45 A, 264 VAC – 75 |
Leakage Current | 300 uA Typical, (N.A. For Class II Option) Touch current <100uA |
Efficiency | 93%(48V,58V), 91%(24V,30V), 90%(12V,15V) |
Hold-up Time | >10 ms typical |
Power Factor | exceeds 0.95 with Full Load, Active PFC |
Output Power | Forced cooling : 120W with 300LFM (refer mechanical dimension) Convection cooling : 100W (for input 100-264 VAC) (de-rate linearly to 80W @ 85VAC) |
Output Voltage Adjustability | +/-3% |
Line Regulation | +/-0.5% |
Load Regulation | +/-1% |
Transient Response | 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% ,recovery time < 5 ms |
recovery time | 55ms typical |
Set Point Tolerance | +/-1 |
Over Current Protection | >110% |
Over Voltage Protection | 110 to 140%, Latch type (AC recycling required) |
Short Circuit Protection | Hiccup mode |
Switching Frequency | 60 KHz |
Operating Temperature | PFC – 70 to 130 KHz, PWM – 50-80 KHz |
Operating Temperature | - 40 to + 70°C |
Storage Temperature | - 40 to + 85°C |
Relative Humidity | 5% to 95%, noncondensing |
Altitude | Operating:16,000 ft.; Nonoperating: 40,000 ft. |
MTBF | >3.00m Hours, Telcordia -SR332-issue 3 |
Isolation Voltage | Input to Output – 4000 VAC medical applications Input to GND - 1500 VAC (Not Applicable For Class II Option) Output to GND- 1500VAC for type BF , 500 VAC for type B (Not Applicable For Class II Option) |
Cooling | Primary to Secondary: 2 MOPP, Primary to Earth: 1 MOPP, Secondary to Earth: 1 MOPP |
Model Number | Description | Voltage | Max. Load (Convection) | Max. Load (300 LFM) | Ripple |
---|---|---|---|---|---|
FSP120-1K20M1 | with Screw Terminal | 12 V | 8.33A | 10.0 A | 1% |
FSP120-1K20M1-II | with Screw Terminal | 12 V | 8.33A | 10.0 A | 1% |
FSP120-1K21M1 | with Molex Connector | 12 V | 8.33A | 10.0 A | 1% |
FSP120-1K21M1-II | with Molex Connector | 12 V | 8.33A | 10.0 A | 1% |
FSP120-1K30M1 | with Screw Terminal | 15 V | 6.66A | 8.0 A | 1% |
FSP120-1K30M1-II | with Screw Terminal | 15 V | 6.66A | 8.0 A | 1% |
FSP120-1K31M1 | with Molex Connector | 15 V | 6.66A | 8.0 A | 1% |
FSP120-1K31M1-II | with Molex Connector | 15 V | 6.66A | 8.0 A | 1% |
FSP120-1K40M1 | with Screw Terminal | 24 V | 4.16A | 5.0 A | 1% |
FSP120-1K40M1-II | with Screw Terminal | 24 V | 4.16A | 5.0 A | 1% |
FSP120-1K41M1 | with Molex Connector | 24 V | 4.16A | 5.0 A | 1% |
FSP120-1K80M1 | with Molex Connector | 24 V | 4.16A | 5.0 A | 1% |
FSP120-1K80M1-II | with Screw Terminal | 48 V | 2.08A | 2.5A | 1% |
FSP120-1K81M1 | with Screw Terminal | 48 V | 2.08A | 2.5A | 1% |
FSP120-1K81M1-II | with Molex Connector | 48 V | 2.08A | 2.5A | 1% |
FSP120-1K50M1 | with Molex Connector | 48 V | 2.08A | 2.5A | 1% |
FSP120-1K50M1-II | with Screw Terminal | 30 V | 3.33A | 4.0 A | 1% |
FSP120-1K51M1 | with Screw Terminal | 30 V | 3.33A | 4.0 A | 1% |
FSP120-1K51M1-II | with Molex Connector | 30 V | 3.33A | 4.0 A | 1% |
FSP120-1K70M1 | with Molex Connector | 30 V | 3.33A | 4.0 A | 1% |
FSP120-1K70M1-II | with Screw Terminal | 58 V | 1.72A | 2.07A | 1% |
FSP120-1K71M1 | with Screw Terminal | 58 V | 1.72A | 2.07A | 1% |
FSP120-1K71M1-II | with Molex Connector | 58 V | 1.72A | 2.07A | 1% |
FSP120-CK | metal cover kit accessory |
NOTES
- Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
- Class II means without input Earth connection.
- Specifications are for nominal input voltage, 25°C unless otherwise stated.
- -40 to 0°C startup is guaranteed with spec deviation in output ripple and voltage regulation.
- Functional, not approved.
Datasheet
IEC 60601-1 120W