Industrial Power Supply 120W

  • 3” x 2” Footprint
  • Height 1” above PCB
  • 120 Watts with Forced Air Cooling
  • Efficiency up to 93%
  • -40 to 70 °C degree operating temperature
  • Thermal Shut-down protection
  • >3.00m Hours, Telcordia-SR332-issue 3
  • Standby Power < 0.3W

Detailed description

Electrical performance
Input voltage85-264 VAC/390 VDC 4 , Universal (see derating under output power)
Input frequency47-63 Hz
Input current115V AC: 1.2A (max.), 230V AC: 0.65A (max.)
No load powerless than 0.3W typical
Surge current115 VAC – 25 A, 230 VAC – 45 A, 264 VAC – 75 A
Leakage Current300 uA Typical, (N.A. For Class II Option) Touch current <100uA
Efficiency93%(48V,58V),91%(24V,30V),90%(12V,15V)
Maintenance time>10 ms typical
Power Factorexceeds 0.95 with Full Load, Active PFC
Output powerForced cooling : 120W with 300LFM (refer mechanical dimension)
Convection cooling : 100W (for input 100-264 VAC)
(de-rate linearly to 80W @ 85VAC)
Adjustable output voltage+/-3%
Voltage regulation rate+/-0.5%
Load regulation+/-1%
Transient response25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% ,recovery time < 5 ms
Rise time55ms typical
Setpoint deviation+/-1%
Overvoltage protection>110%
Overvoltage protection110 to 140%, Latch type (AC recycling required)
Short circuit protectionHiccup mode
Switching frequency60 KHz typical
Operating temperature-40 to +70°C
Storage temperature-40 to +85°C
Relative humidity5% to 95% (noncondensing)
AltitudeOperating: 16,000 ft.; Nonoperating: 40,000 ft.
MTBF Life>3.00m Hours, Telcordia-SR332-issue 3
Insulation VoltageInput to Output – 3000V AC for ITE application

ModelDescriptionVoltageMaximum load
(Convection)
Max. Load
( 300 LFM )
Maximum loadRipple
FSP120-1K20with Screw Terminal12 V8.33A10.0A0.0 A1%
FSP120-1K21with Molex Header12 V8.33A10.0A0.0 A1%
FSP120-1K30with Screw Terminal15 V6.66A8.0A0.0 A1%
FSP120-1K31with Molex Header15 V6.66A8.0A0.0 A1%
FSP120-1K40with Screw Terminal24 V4.16A5.0A0.0 A1%
FSP120-1K41with Molex Header24 V4.16A5.0A0.0 A1%
FSP120-1K80with Screw Terminal48 V2.08A2.5A0.0 A1%
FSP120-1K81with Molex Header48 V2.08A2.5A0.0 A1%
FSP120-1K50with Screw Terminal30 V3.33A4A0.0 A1%
FSP120-1K51with Molex Header30 V3.33A4A0.0 A1%
FSP120-1K70Screw terminal58 V1.72A2.07A0.0 A1%
FSP120-1K71With Molex connector58 V1.72A2.07A0.0 A1%
FSP120-CKmetal cover kit accessory

Note

  1. Ripple voltage is peak-to-peak, at a bandwidth of 20MHz, the output is connected in parallel with 10μF bile capacitance and a 0.1μF capacitor, tested at rated input voltage and output load range;
  2. Electrical performance is only for nominal input voltage and ambient temperature of 25°C, unless otherwise stated;
  3. – 40 °C 0 °C can guarantee start-up, but the output ripple voltage and voltage adjustment rate will be different
  4. Feature is not certified

Mechanical Specifications
Input Connector (J1) Option 1Molex: 39357-0003
Tyco: 2-1776112-3
Option 2Molex: 1722861103
(Mating conn: Molex 1722561003)
DC Output Connector (J2) Option 1Molex: 39357-0004
Tyco: 2-1776112-4
Option 2Molex: 1722861104
(Mating conn: Molex 1722561004)
Size3 x 2 x 1.18inch (76.2 x 50.8 x 30.1 mm)
Weight150g
EMC
CE MarkComplies with LVD Directive
Conducted EmissionsEN55022 - B, CISPR22 - B, FCC PART15 - B
Static DischargeEN61000-4-2, Level-3
RF Field SusceptibilityEN61000-4-3, Level-3
Fast Transients/BurstsEN61000-4-4, Level-3
Radiated EmissionsLevel A radiated, Level B radiated with external core
Surge SusceptibilityEN61000-4-5, Level-3
Harmonic CurrentEN61000-3-2, Class D
Safety
Safety Standard(s)IEC/EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013,
UL 60950-1, 2nd Edition, CAN/CSA C22.2 No. 60950-1-07, 2nd Edition
Approval AgencyUL, C-UL
Safety File Number(s)UL: E135662
CCC Standard(s)GB9254-2008;GB4943.1-2011;GB17625.1-2012  CNCA-C09-01:2014
CQC File Number(s)2016010907856054
Environmental protection
RoHS VersionFSP075 Series Meets European RoHS Requirements (Directive 2011/65/EU)


Datasheet